Operating manualRead the instructions prior to performing any task!REMKO Smart WP MANAGERSmart-Control for WKF/WKF-compact 85/120/180Manual for experi
3 Operation - User level 3.1 Menu structure of the con-troller The following information is primarily directed atsystem operators. Specialists
Overview of the menus (User level)LEVEL 03D houseHot waterRoom climateLEVEL 1Information Settings MessagesLEVEL 2BasicinformationSolarBasicsettingsSol
"3D house" animationOnce the Smart-Control commissioning wizard hasbeen completed, you will see the home screen withthe 3D house. Pressing t
Explanation of operating modes:Standby - the controller waits for the next requestDispensing operation - hot water is being dis-pensedCirculation - ci
Favourites menu: for the userUsing the rotary knob (turning it clockwise) you canaccess other views. They allow you to rapidly andeasily adjust the mo
One-off hot water / party modeActivating Party mode (select with the rightsoftkey) causes the next window of time withreduced heating to be disregarde
CO2 savingsCO2 savings specifies how much CO2 emissionshave been avoided. The calculation of CO2 savingsis based on the amount of renewable energy gen
"Information" menu item - UserThis menu contains information about the current operating status of the system. The menu is opened withthe
"Information" menu item (continued) - UserAuthorisa-tion levelLevel 2menu itemLevel 3 menu item InfoSolarPump A01 / Pump control signal A4
"Information" menu item (continued) - UserAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item InfoFloorheating cycleAbs.prim. pump speed
Made by REMKOTranslation of the original operating manualRead these operating instructions carefully before commis-sioning / using this device!These
"Information" menu item (continued) - UserAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item InfoHeat pumpHeat pump statusYou can findm
"Settings" menu item - UserIn this menu you can configure the settings. For example, you can adjust hot water and heating tempera-tures or
"Settings" menu item (continued) - UserAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item Level 4 menu item InfoHeating /coolingModeRoo
4 Operation - Expert level 4.1 Commissioning wizard The commissioning wizard which starts when thecontroller is activated is intended for pro
Setting the countrySelect the country with the rotary knob and confirmthe entry with "OK".Fig. 30: Selecting a countryMenu item ParameterFac
Menu item ParameterFactorysettingNederlandsPolskiPress "Next".Setting the time zone for the winter timeSelecting the time zone for the winte
Activating the heat pumpThe controller detects automatically that a heatpump has been connected. If necessary, activatethe heat pump (select with the
ReheatingDesired charging temperature for the hot waterstorage tank.Set temperature to which conventional reheatingshould heat the storage tank to ens
Circulation type(dependent on which probes are used)Impulse circulation:If briefly dispensing water triggers an impulse onthe flow-operated safety dev
Impulse-guided circulation - Disable switch-onAfter the running time of the circulation pump, thepump cannot be started again while disable switchon i
Table of contents1 Safety and usage instructions...
Heating-curve heating cycle modeThe heating curve can be adjusted in three points,according to the structure and location-related con-ditions of the b
System separationActivation if the floor heating cycle is separated bya heat exchanger.To control a separate heating cycle pump with asystem separatio
Standard inlet temperature:the standard inlet temperature corresponds to theset temperature of the heating water at thestandard outside temperature in
BuildingtypeHeat retention abilityRecom-mended valueLight Low heat retention ability, e.g. prefab / wood-frame houses approx. 10hMedium Moderate heat
Cooling functionActivate (select with the rotary knob and confirmwith "OK") if the building is to be actively cooledwith the heat pump in su
Menu item Parameter Factory settingPump type(solar cycle)AsynchronouspumpEC pumpSelectionaccording topump typeinstalled in thesolar cycleSolar speed c
Setting the impulse rate of the solar mediumflow rate probeThe impulse rate may only be changed (select withthe rotary knob and confirm with "OK&
Set temperature of the storage tank duringsolar chargingOnce the solar set temperature is reached, thesolar cycle pump is switched off. With the colle
4.2 Template hydraulic diagrams with installation parameters NOTICE!The following template hydraulic systems are only to be used as a planning aid
Menu item Parameter Factory settingControl panel address Control panel 1-3 Control panel 1Country Deutschland - Slovensko DeutschlandLoad setting Acce
1 Safety and usageinstructions 1.1 General safety notes Carefully read the operating manual before com-missioning the units for the first time.
Menu item Parameter Factory settingCooling function Activated / Deactivated Deactivated / Enable as requiredSeparate cooling cycle Activated / Deactiv
Hydraulic diagram for heat pump assembly WKF FrankfurtFunctions: heating and hot water, operating mode: monoenergetic or bivalent alternative. Solar p
Menu item Parameter Factory settingCirculation running time 1 min - 15 mins 5 minsDisable switch-on 1 min - 15 mins 5 minsCirculation type Impulse or
Hydraulic diagram for heat pump assembly WKF Dortmund 2Functions: heating or cooling and hot water, operating mode: monoenergetic.Only one cycle is po
Menu item Parameter Factory settingCirculation running time 1 min - 15 mins 5 minsDisable switch-on 1 min - 15 mins 5 minsCirculation type Impulse or
Hydraulic diagram for heat pump assembly WKF compact StuttgartFunctions: heating or cooling and hot water, operating mode: monoenergetic.Only one cycl
Menu item Parameter Factory settingCirculation type Impulse or Temperature ImpulseCirculation running time 1 min - 15 mins 5 minsDisable switch-on 1 m
Hydraulic diagram for heat pump assembly WKF compact Mannheim bivalentFunctions: heating or cooling and hot water, operating mode: monoenergetic or bi
Menu item Parameter Factory settingCirculation type Impulse or Temperature ImpulseCirculation running time 1 min - 15 mins 5 minsDisable switch-on 1 m
Hydraulic diagram for heat pump assembly WKF Düsseldorf 2Functions: heating or cooling and hot water, operating mode: monoenergetic.Only one cycle is
1.6 Safety notes for the operator The operational safety of the units and compo-nents is only assured providing they are used asintended and in a f
Menu item Parameter Factory settingCirculation running time 1 min - 15 mins 5 minsDisable switch-on 1 min - 15 mins 5 minsCirculation type Impulse or
Hydraulic diagram for heat pump assembly WKF compact Stuttgart SolarFunctions: heating or cooling/hot water and solar, operating mode: monoenergeticOn
Menu item Parameter Factory settingCirculation running time 1 min - 15 mins 5 minsDisable switch-on 1 min - 15 mins 5 minsCirculation type Impulse or
Hydraulic diagram for heat pump assembly WKF Frankfurt SolarFunctions: heating/hot water and solar, operating mode: monoenergetic or bivalent possible
Menu item Parameter Factory settingCirculation running time 1 min - 15 mins 5 minsDisable switch-on 1 min - 15 mins 5 minsCirculation type Impulse or
4.3 Menu structure of the controller "Information" menu item - ExpertThis menu contains information about the current operating status
"Information" menu item (continued) - ExpertAuthorisa-tion levelLevel 2menu itemLevel 3 menu item InfoSolarPump A01 / Pump control signal
"Information" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item InfoFloorheating cycleAbs.prim. pump spe
"Information" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item InfoHeat pumpHeat pump statusYou can fin
"Information" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item Level 4 menu item InfoMeter read-ingsSol
1.11 Transport and packaging The devices are supplied in a sturdy shipping con-tainer or inside the heat pump casing. Pleasecheck the equipment imm
"Information" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item Level 4 menu item InfoMeter read-ingsHou
"Information" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item InfoChecklistCollector temp. S01You can
"Settings" menu item - ExpertIn this menu you can configure the settings. For example, you can adjust hot water and heating tempera-tures
"Settings" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item Level 4 menu item InfoBasic settings System
"Settings" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item Level 4 menu item InfoSolarCollectorMax. te
"Settings" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item Level 4 menu item InfoHot waterDomestic wat
"Settings" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item Level 4 menu item InfoHeating /coolingBuild
"Settings" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item InfoSolar heatingMin. pump speedYou can fin
"Settings" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item Level 4 menu item InfoHeat pumpBasic settin
"Messages" menu item - ExpertPressing "OK" (right softkey) takes you to submenus of the menu item "Messages".This is w
2 Operation - General 2.1 Design and functions Overview of the controls34546712 2Fig. 1: Controls of the Smart-Control1: SD card2: Movement
"Message" menu item (continued) - ExpertManual mode (relay test) (continued) Parameter Selection parameter Cooling changeover valve Ou
"Message" menu item (continued) - ExpertManual mode (relay test) (continued) Parameter Selection parameter Panel heating cycle pump st
"Message" menu item (continued) - ExpertManual mode (probes) (continued) Parameter Selection parameter Circulation paddle switch Probe
"Message" menu item (continued) - ExpertManual mode (probes) (continued) Parameter Selection parameter Solar cycle return temp. Probe
5 Installation 5.1 Room installation of theSmart-Control NOTICE!Only use the unit in dry areas and protect itfrom electromagnetic radiation.The
6 Electrical wiring 6.1 Structure electrical connection I/0 module Cable cross-sections corresponding to the supplied connection cable!Place the
6.2 Terminal assignment / legend Terminal assignmentTerminal Input Output Signal Connection layoutPW X Power supply I/O 230VPP X Power supp
Terminal Input Output Signal Connection layoutA11 X Changeover valve 2. heat generatorA12 X Changeover valve solar / 2. storage tank poolA13
7 PV power utilisation 7.1 Higher energy consumptionfrom the combination of heatpump and PV plant Ideal for new and existing photovoltaic plants
7.2 Using the PV power surplus The self-generated photovoltaic power is used inthe first instance for power needs in the home(lighting, household a
Navigation and changing parametersCalling up the main menuPress the menu key until the menu items "Informa-tion", "Settings" and &
7.3 Systems with aphotovoltaic plant SystemsThe smart heating function can be used with thefollowing variants:n Hybrid heat pumpn Split air/water h
8 Index CChanging parameters... 8Connection of the controller to the electricitymeters and inverter...
REMKO Smart WP MANAGER 82
ConsultingThanks to intensive training, our consultants are always completely up-to-date in terms of technical knowledge. This has given us the reputa
Select "Change" (right softkey). The select valueappears marked in blue.Language / TimeTime: 14 : 54Cancel2/7NextFig. 9: Selecting a parame
Komentáře k této Příručce