Strany 1 - REMKO CMF / CMT

Edition GB – W11REMKO CMF / CMTCMF 120-1P, CMF 160-1P, CMT 120-1P, CMT 160-1PInverter heat pumpsPlanning Guide and Installation Manual Instructions fo

Strany 2

REMKO CMF / CMTDefrost by circulation reversalAt temperatures below about +5°C, humidity freezes in the evaporator (outdoor module) and an ice layer c

Strany 3 - Contents

CMF SeriesWe offer two different indoor-unit designs. The wall-mounted CMF Series is equipped with a circulation pump and a safety module on the water

Strany 4

REMKO CMF / CMTCMT SeriesIn addition, the indoor module of the CMT series is fitted with a hot-water buffer storage. An electric booster heater with a

Strany 5

Outdoor unit CMT 120-1PIndoor unit CMT 120-1PFanOutdoor areaRefrigerant lines 3/8" and 5/8"Mains cable Indoor unit (3x1.5mm2)Indoor area

Strany 6 - 75%* of the heat

REMKO CMF / CMTÖOutdoor unit CMT 160-1PIndoor unit CMT 160-1PFanOutdoor areaRefrigerant lines 3/8" and 5/8"Mains cable Indoor unit (3x1.5mm2

Strany 7 - Decompression

These instructions are to be observed when installing the entire system. The device should be delivered as near as possible to the site of installa

Strany 8

REMKO CMF / CMT The wall bracket is to be attached to the wall with the fasteners supplied and the indoor module hooked onto it. The wall must posse

Strany 9

The device may be attached only to a load-bearing structure or wall. Ensure that the outdoor module is installed only vertically. The installation s

Strany 10

REMKO CMF / CMTMinimum distances in mm for CMF/CMT 120-1P and in brackets for the CMF/CMT160-1P depending on the enclosureNext to a wall, air outlet

Strany 11 - Versions

Condensate- and melt-water drainageSpecial attention must be directed to the topic of condensate- and melt-water drainage. In every case, steps must b

Strany 13 - Installation instructions

REMKO CMF / CMTHydraulic connection We recommend installing a buffer storage unit as a hydraulic switch for hydraulically isolation of the heating ci

Strany 14

Corrosion protectionOxygen always plays a role if metal materials in a heating system corrode. pH values and the salt content also play a major role.T

Strany 15 - Liquid line

REMKO CMF / CMTElectrical connection It is necessary to lay a power-supply cable both to the outdoor module and, separately, to the indoor module.

Strany 16

Electrical connection - indoor moduleThe following instructions describe the electrical connection of the CMF and CMT Series indoor module. Shown her

Strany 17

REMKO CMF / CMTElectrical connection - outdoor module The side wall of the the unit is to be removed by means of loosening the screws in order to c

Strany 18

Temperature sensors External sensor The number of sensors required can vary with the type of system. In the indoor module (F11), the collector sens

Strany 19

REMKO CMF / CMT The outdoor- and the indoor modules are connected with two copper pipes of refrigerator quality having the dimensions “ and “ (REMKO

Strany 20 - Indoor unit

Monitoring for leaks Connect the manometer to at least one Schrader valve on the shut-off valves of the outdoor module. The leak test must to be un

Strany 21 - Corrosion protection

REMKO CMF / CMTControl panel Mode switch Position I: Normal operation This switch turns on the system. The heat pump and a possible 2nd heat source

Strany 22 - (Merlin I/O circuit board)

Notes for commissioning The commissioning and programming of the heat-pump manager may be carried out only by an installer authorized by REMKO. N

Strany 23 - Electrical connection

ContentsRead these operating instructions carefully before commissioning / using this device!These instructions are an integral part of the system an

Strany 24

REMKO CMF / CMTHeat pump manager Multi-Talent Plus (heat flow meters)Display levelThe displays relevant to the heat flow meters are called up with the f

Strany 25

Troubleshooting and customer serviceThe unit has been manufactured using state-of-the-art production methods and tested several times to ensure its co

Strany 26

REMKO CMF / CMTDisplay Fault description/noteHeat-pump fault (E 54)Heat pump fault The flow monitor has tripped. A flow problem has occurr

Strany 27

In the event that the red control lamp lights up on the indoor module, then the fault is on the outdoor module. Two LEDs are visible after removing th

Strany 28

REMKO CMF / CMTUnit dimensionsDimensions outdoor module CMF / CMT 120-1PDimensions outdoor module CMF / CMT 160-1P45070010501338450135034

Strany 29 - OK

Unit dimensionsPipe-socket arrangementOpening for installing the E-heater controllerRefrigerant pipe, 3/8"Condensate-drain socket AD=22Fill- and

Strany 30

REMKO CMF / CMTExternal dimensions, CMT Series indoor moduleDimensions indoor module CMTTilt height: 1,900 mm5506059105509351670Overall dimensions: ma

Strany 31



Strany 32

REMKO CMF / CMTCircuit diagramsPlatine WP-Manager (Merlin I/O circuit board)Power plant- Disable/ enableGreen indicator light Demand Outdoor unitCircu

Strany 33

Circuit diagram (continued)Load pump Indoor unitCircuit diagram WP02Switching valve 2. heat sourceOPENCLOSEDSpecial accessorieselectro heatingPlatine

Strany 34

REMKO CMF / CMTSafety notesCarefully read the operating instruction before placing the equipment in service. It provides useful tips and information

Strany 35 - Unit dimensions

REMKO CMF / CMTCircuit diagram (continued)Circuit diagram WP03Special accessorieselectro heatingFlow monitor *) or Jumper **)Circuit board WP manager

Strany 36

Circuit diagram (continued)Platine WP-Manager (Merlin I/O circuit board)Circuit diagram WP04Red indicator lightOutdoor-module failureMF4 outlet for so

Strany 37 - 

REMKO CMF / CMTCircuit diagram (continued)

Strany 38

Circuit diagram (continued)Circuit diagram WP06 Enable 2Heat source(potential-free normally open ornormally closed switch)Enable compressorEnable Cool

Strany 39 - Circuit diagram (continued)

REMKO CMF / CMTCircuit diagram (continued) Platine WP-Manager (Merlin I/O circuit board)Circuit diagram WP07PumpHK 1OPEN3-waymixerHK 23-wayswitching v

Strany 40 - Circuit board WP manager

Circuit diagram (continued)Platine WP-Manager (Merlin I/O circuit board)Circuit diagram WP08Control panel in the indoor module(Interface PAC-IF010 B-E

Strany 41

REMKO CMF / CMTTerminal block/legendTermi-nalConnection layout (low-voltage sensor)X3. EarthX3.1 CAN-Bus HX3.2 CAN-Bus +X3.3 CAN-Bus LX3.4 CAN-Bus -X

Strany 42

Diagramm Heizleistung W35_8 kW0246810121416-15 -14 -13 -12 -11 -10 -9 -8 -7 -6 -5 -4 -3 -2 -1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20Char

Strany 43

REMKO CMF / CMTCharacteristic curvesDiagramm COP W45_8 kW0123456-15 -14 -13 -12 -11 -10 -9 -8 -7 -6 -5 -4 -3 -2 -1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14

Strany 44

Characteristic curvesPerformance number CMF / CMT 120-1PDiagramm COP W55_8 kW01234-15 -14 -13 -12 -11 -10 -9 -8 -7 -6 -5 -4 -3 -2 -1 0 1 2 3 4 5 6 7 8

Strany 45

Care and maintenanceRegular care and maintenance serves to ensure trouble-free operation and long service-life of the heat-pump system.Care The indoo

Strany 46

REMKO CMF / CMTCharacteristic curvesPerformance number CMF / CMT 160-1PDiagramm COP W35_14kW01234567-15 -14 -13 -12 -11 -10 -9 -8 -7 -6 -5 -4 -3 -2 -1

Strany 47 - Rated frequency 96/99 Hz

Characteristic curvesPerformance number CMF / CMT 160-1PDiagramm COP W45_14kW012345-15 -14 -13 -12 -11 -10 -9 -8 -7 -6 -5 -4 -3 -2 -1 0 1 2 3 4 5 6 7

Strany 48

REMKO CMF / CMTDiagramm COP W55_14kW01234-15 -14 -13 -12 -11 -10 -9 -8 -7 -6 -5 -4 -3 -2 -1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20Diagra

Strany 49

Pump-characteristic curves, indoor module charging pumpLevelOutput in WCurrent in AI 25 0,12II 35 0,16III 45 0,20Sound pressure levelLevelOutput in

Strany 50 - Rated frequency 76/77 Hz

REMKO CMF / CMTOverall sound pressure levels for outdoor module CMF/CMT 120-1P 25 63 125 250 500 1000 2000 4000 8000 A L304050607080dBHz Excluded ran

Strany 51

Overall sound pressure levels for outdoor module CMF/CMT 160-1PExcluded rangeOutput A-bewCursor: (A)Power=67.1 dBMiddle frequency (Hz)25 31,50 40 50 6

Strany 52

REMKO CMF / CMTClimatic region: -10°CExisting buildings with hot-water heating (share 18%)TypeCOPAnnual performance number with inlet/outlet tem-perat

Strany 53 - Sound pressure level

Climatic region: -10°CExisting buildings with hot-water heating (share 18%)TypeCOPAnnual performance number with inlet/outlet tem-perature differentia

Strany 54

REMKO CMF / CMTSeries CMF 120-1P CMT 120-1P CMF 160-1P CMT 160-1PFunction Heating or CoolingInverter technologyREMKO SuperTecSystem Split-Air/WaterHe

Strany 55

Device display for outdoor module CMF 120-1P, CMT 120-1PSpare parts listNo. Designation CMF 120-1P CMT 120-1PEDP -number EDP -number1 Compressor 11200

Strany 56

REMKO CMF / CMTEconomical and environmentally-conscious heatingThe burning of fossil-based energy sources in order to generate power creates severe co

Strany 57 - Climatic region: -16°C

REMKO CMF / CMTDevice display for outdoor module CMF 160-1P, CMT 160-1PSpare parts listNo. Designation CMF 160-1P CMT 160-1PEDP -number EDP -number1 C

Strany 58

Device display for indoor module CMF 120-1P, CMF 160-1PWe reserve the right to modify the dimensions and constructional design as part of the ongoing

Strany 59 - Spare parts list

REMKO CMF / CMTSpare parts listNo. Designation CMF 120-1P CMF 160-1P1 Housing 1120009 11200092 Front panel 1120006 11200063 Door with hinge 1120005 11

Strany 60

Device display for indoor module CMT 120-1P, CMT 160-1P19We reserve the right to modify the dimensions and constructional design as part of the ongoin

Strany 61

REMKO CMF / CMTSpare parts listNo. Designation CMT 120-1P CMT 160-1P1 Housing2 Front panel, upper 1120061 11200613 Front panel, centre 1120062 1120062

Strany 62

EC – Declaration of Conformity We do hereby declare that the devices named below, produced and sold by us, satisfy the relevant basic requirements of

Strany 63

REMKO CMF / CMTGeneral termsDefrostAt outdoor temperatures below 5°C it is possible that ice may form on the evaporators of air/water heat pumps. The

Strany 64

Coefficient of performance The current ratio of thermal output produced by the heat pump to the consumed electrical power is referred to as the coeffi

Strany 65 - REMKO GmbH & Co. KG

ConsultingThanks to intensive training, our consultants are always completely up-to-date in terms of technical knowledge. This has given us the reputa

Strany 66

Evaporation LiquefyingCondensingDecompressionFunctional diagram heating inverter heat pumpHeating pump outdoor unitOutdoor areaHeat pump indoor unitIn

Strany 67

REMKO CMF / CMTLayoutBuilding type Specific heating output in W/m2Passive energy house 10Low-energy house built in 2002 40according to energy conserva

Strany 68 - REMKO INTERNATIONAL

Characteristics of REMKO inverter heat pumpsOutdoor air as a heat sourceAn air/water heat pump absorbs energy from the outdoor air as its heat source