Assembly and operating instructions
Read the instructions prior to performing any task!
REMKO fresh water station EFS 25
Instructions for user and specialist
0039-2013-04 Edition 1, en_GB
Zobrazit stránku 0
1 2 3 4 5 6 ... 23 24

Shrnutí obsahu

Strany 1 - 0039-2013-04 Edition 1, en_GB

Assembly and operating instructionsRead the instructions prior to performing any task!REMKO fresh water station EFS 25Instructions for user and specia

Strany 2

4 Design and planning 4.1 General Information The fresh water station is a fresh water modulethat heats domestic water according to the contin-u

Strany 3 - Table of contents

4.2 Design of the storage tank You can use the following table to calculate the approximate required volume of the buffer tank.Temperature in buffe

Strany 4

5 Circulation operation The fresh water station is (optionally) equippedwith a circulation pump. Three possible operatingmodes are stored in the co

Strany 5

Fig. 4: Distance between the holes6. Hang the fresh water module onto thescrews. Tighten the screws so that the insu-lation on the sides is flush to t

Strany 6

7 Commissioning (specialist) 7.1 General Information NOTE:Open the valves in the pipes and the fresh waterstation slowly, in order to prevent pr

Strany 7 - Technical data

7.3 Commissioning the controller DANGER!Danger due to electric shock!Check whether the probes and pumps to thecontroller are connected and whether

Strany 8

7.4 Maximum dispensing medium flow rate The following diagram shows the maximum dispensing medium flow rate depending on the storage tanktemperatur

Strany 9 - Unit description

The following diagram shows the maximum dispensing medium flow rate if the hot water temperature is 45°C at the dispensing connection, after being mix

Strany 10 - REMKO fresh water station

7.5 Setting the Temperature Set the required (maximum) domestic hot water temperature on the controller under "Para".To ensure that scald

Strany 11 - Design of the storage tank

7.6 Commissioning report System operator System location Serial numbers REMKO EFS25 - Medium flow rate probes - Controller - Software version

Strany 12

Installation and operating instructions (translation of the orig-inal)Read these operating instructions carefully before commis-sioning / using this d

Strany 13

9 Depiction of spare parts (specialist) Depiction of spare parts EFS 2523713474568Fig. 10: Spare parts EFS 25We reserve the right to modify the dim

Strany 14

Spare parts list EFS 25No. Description EFS 251 Controller 260156-92 Grundfoss circulation pump UPM 2-15/75 CIL 2 260155-23 Screw-in probe 15 mm G 1/4

Strany 15 - Commissioning the controller

10 Index CCirculation operation... 12Commissioning the controller... 15Controller,

Strany 17 - [l/min]

ConsultingThanks to intensive training, our consultants are always completely up-to-date in terms of technical knowledge. This has given us the reputa

Strany 18

Table of contents1 Safety and usage instructions...

Strany 19 - Maintenance

1 Safety andusage instructions 1.1 General safety notes Carefully read the operating manual before com-missioning the units for the first time.

Strany 20

1.6 Safety instructions for the oper-ator The operational safety of the units and compo-nents is only assured providing they are used asintended an

Strany 21

1.9 Intended use The fresh water module is only permitted to beinstalled in heating systems between the buffertank and the domestic water circuit.

Strany 22

2 Technical data 2.1 Unit data Series EFS 25Operating dataMaximum permitted pressure, primary bar 3Maximum permitted pressure, secondary bar 10O

Strany 23

Unit data (continued)Series EFS 25DimensionsHeight (with insulation) mm 645Width (with insulation) mm 344Depth (with insulation) mm 249Top axis-centre

Strany 24 - REMKO INTERNATIONAL

3 Unit description The fresh water station is a pre-installed valvegroup that was checked for leak tightness; it isused to transfer heat between th